Integrated frequency inverters with safe stop function

Integrated frequency inverters with safe stop function
The NORD SK 200E series of frequency inverters for distributed applications (motor-integrated inverters) includes certified protection for applications up to SIL3.

Operator safety at the workstation is an absolute necessity at all times. When a safety circuit is triggered because a cover or protective door has been opened, any risk of accident linked to drives or rotating parts must be eliminated.

Moreover, because of the costs of production downtime, it is essential that installations are unavailable for as short a time as possible. Economic efficiency demands fast restarts after machine stops for safety reasons.

While optimized to provide economical drive solutions, the NORD DRIVESYSTEMS frequency inverters for distributed applications SK200E are equipped with several safety functions which, depending on the switching device, guarantee safe stopping procedures for high-risk applications, in compliance with category 4 or Performance Level E according to standard EN 13849-1.

Conventional frequency inverters in this performance class prevent the motor from restarting by cutting the supply voltage or the 24 V supply control.

By contrast, the SK 21xE and SK 23xE models are equipped with a certified pulse blocking device as well as dedicated digital inputs for the "voltage disconnection" and "quick safe stop" functions. These functions enable Stop Category 1 (controlled braking of the motor in accordance with SIL1), followed by "Safe Torque Off" (to prevent torque from being present on the motor, in accordance with SIL3) or Stop Category 0 (in accordance with SIL3) according to standard EN 60204-1.

Since the voltage supply is blocked without shutting down the control or the power electronics, the inverters remain on standby, ready to restart, without requiring a reset after the safe stop has been triggered. In addition to high availability, the inverters' safety technology offers other economic advantages: firstly, contactors are not required; secondly, since the safety functions are activated electronically, regular maintenance and replacement of electromechanical contacts become unnecessary.