Precise Optical In-Line Thickness Measurement with Micro-Epsilon

Precise Optical In-Line Thickness Measurement with Micro-Epsilon

Thickness measurement of strip products is becoming increasingly essential in modern production plants. Growing quality requirements, faster manufacturing processes and tighter tolerances therefore call for metrology solutions for in-line thickness testing. Micro-Epsilon's optical sensors are ideally suited to this type of measurement task.

In addition to sensors, Micro-Epsilon also offers turnkey measuring systems, such as the new thicknessGAUGE, which is available in C-frame and O-frame models. The compact system is stable, powerful and delivers values accurate to the micrometer for in-line inspection of material thickness at 100 %. Depending on the requirements of the measurement task, the thickness measuring system, which works with laser sensors, laser scanners or confocal chromatic sensors, can thus be applied to a large number of different surfaces and materials. The complete system is therefore used in many industries, such as the metal industry for strips and sheets, battery production on coated and uncoated foils, and materials technology on plastic films, fabrics, wood or ceramics.

Advantages of optical sensors for thickness measurement


For geometric thickness measurement, the two optical sensors mounted on the C-frame or O-frame each measure above and below the target. A calibration process lasting only a few seconds determines the distance between the two sensors. Using the difference method, the thickness value can now be determined precisely, directly in the in-line process, from the calibrated working range and the subtraction of the two sensor signals. Optical sensors measure without contact and offer a long service life. Compared with tactile measuring devices, optical sensors react directly and therefore much faster to changes in thickness. Compared with radiometric methods, measurements are much more precise, because a higher spatial resolution is achieved and no material-dependent calibration is required. Micro-Epsilon thicknessGAUGE measuring systems are temperature-compensated, which means they can also be used in fluctuating ambient temperatures.

Design of the C-frames and O-frames
thicknessGAUGE systems are available with a C-frame or an O-frame. With the C-frame, the sensors are permanently mounted on the upper and lower arms. C-frames are particularly suitable for applications on narrow strips, because the vibration sensitivity of the upper arm increases with the width of the material. The advantage of the C-frame is that it can be removed completely from the line during threading or in dangerous situations.

The O-frame is closed around the object to be measured, so the object must be placed through the frame. Owing to its shape, the O-frame is more stable than the C-frame. The arms can therefore be longer, allowing wider targets to be measured.

Micro-Epsilon thicknessGAUGE, different measuring principles for flexible application options


The thicknessGAUGE system is available in three different versions based on various sensor technologies. The fields of application include thickness control after rolling, calendering, extrusion, pressing and sanding, double-layer detection, as well as quality control and documentation. Thanks to the non-contact measuring principle of optical sensors, it is possible to measure all materials and composites as well as pressure-sensitive, rough, soft, sticky or glowing surfaces.

thicknessGAUGE.laser
thicknessGAUGE.laser systems are equipped with laser triangulation sensors and offer both good value for money and high measuring speed and accuracy. The systems are used to measure the thickness of wood, plastic and metal with an accuracy of ±4 to ±20 µm and a measuring rate of up to 4 kHz.

thicknessGAUGE.confocal
Micro-Epsilon thicknessGAUGE.confocal systems are equipped with confocal chromatic sensors. They work with a measuring rate of up to 5 kHz and an accuracy of ±0,25 µm. The special feature is that thickness measurement can also be performed on reflective and shiny measuring objects as well as on transparent and semi-transparent films. Typical applications are found in the control of calendering, extrusion and coating processes for thin materials.

Battery production: measuring the wet-layer thickness of anode and cathode materials


In the coating process of battery production, the foil is coated continuously or intermittently and over a width of up to 1000 mm. To measure the thickness of the wet-film anode and cathode material, an accuracy of <±1 ?m for an object thickness of 150 to 500 µm is required. A thicknessGAUGE C-frame with two confocal sensors is used for this measurement task. The high accuracy of ±0,25 µm and the measuring speed of up to 5 kHz enable fully automated measurement of the thickness and the complete cross profile.

thicknessGAUGE.laser profile
thicknessGAUGE.laser profile systems are equipped with laser profile scanners that offer a measuring rate of up to 100 Hz and an accuracy of up to ±0,5 µm. Because the scanners project a laser line onto the measuring object, they compensate for the tilt of the strip and also measure structured materials, since the measured values can be averaged along the laser line. They are used, among other things, for measuring the thickness of perforated and embossed plates as well as for roller inspection and quality documentation.

The wear-free thicknessGAUGE systems perform 100 % quality control with high accuracy and maximum flexibility. Various modifications allow them to be optimally adapted to the respective measurement task, just as three different sensor technologies make it possible to measure on a wide variety of surfaces. Thanks to their good value for money, the C-frame and O-frame systems can be used in standard industrial applications as well as in the OEM sector. Calibration is performed automatically, regularly and within seconds. The complete analysis and control software supplied offers the user individual options for storage, processing and adjustment. The thickness measuring systems are suitable for both initial equipment and retrofitting.