There is now a new variant that offers extended diagnostic functions, and another new variant that allows switching of OSSD outputs independently of interlocking.
The PSENslock offers a safe guarding of mobile guards with an electromagnetic interlock for mobile guards, covers and valves in a compact product.
The new variant with an extended diagnostic function offers an additional advantage in the application domains which use several PSENslock: the user immediately detects where an interlock has not been activated, for example due to fouling . This saves time since it is possible to obtain a faster diagnosis in case of malfunction.
The second new variant of the safety guard system allows the OSSDs (Output Signal Switching Device) to be switched regardless of the state of the interlock. This guarantees the user greater flexibility and flexibility in the implementation of his application.
Therefore the PSENslock are designed for applications up to PL e according to EN ISO 13849-1 or SIL 3 according to EN IEC 62061.
Since the mobile guard system is open, it can be connected to all common control units as well as to Pilz control systems - safety logic blocks, PNOZmulti configurable control systems and the PSS automation system 4000. Serial connections are also possible with the PSz safety sensors PSENslock, PSENsgate and the PSENcode encoded safety sensor.
The PSENslock offers a safe guarding of mobile guards with an electromagnetic interlock for mobile guards, covers and valves in a compact product.
The new variant with an extended diagnostic function offers an additional advantage in the application domains which use several PSENslock: the user immediately detects where an interlock has not been activated, for example due to fouling . This saves time since it is possible to obtain a faster diagnosis in case of malfunction.
The second new variant of the safety guard system allows the OSSDs (Output Signal Switching Device) to be switched regardless of the state of the interlock. This guarantees the user greater flexibility and flexibility in the implementation of his application.
Therefore the PSENslock are designed for applications up to PL e according to EN ISO 13849-1 or SIL 3 according to EN IEC 62061.
Since the mobile guard system is open, it can be connected to all common control units as well as to Pilz control systems - safety logic blocks, PNOZmulti configurable control systems and the PSS automation system 4000. Serial connections are also possible with the PSz safety sensors PSENslock, PSENsgate and the PSENcode encoded safety sensor.